<ins id="ukspj"><form id="ukspj"></form></ins>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><xmp id="ukspj"><form id="ukspj"></form><ins id="ukspj"><form id="ukspj"><form id="ukspj"></form></form></ins>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form><ins id="ukspj"><form id="ukspj"></form></ins>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><ins id="ukspj"></ins><ins id="ukspj"><form id="ukspj"><ins id="ukspj"></ins></form></ins>
<xmp id="ukspj"><button id="ukspj"></button>
<xmp id="ukspj"><form id="ukspj"></form>
<ins id="ukspj"></ins>
<form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><ins id="ukspj"></ins>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><xmp id="ukspj"><button id="ukspj"></button><xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj">
<xmp id="ukspj">
<form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj">
<xmp id="ukspj"><button id="ukspj"></button>
<xmp id="ukspj"><form id="ukspj"><form id="ukspj"></form></form>
<xmp id="ukspj"><form id="ukspj"><form id="ukspj"></form></form>
撥號13501151717
產品目錄
  • 水泥砂漿類試驗儀器
  • 混凝土類檢測設備
  • 瀝青類試驗儀器
  • 防水卷材類試驗儀器
  • 砌墻磚系列
  • 土工類試驗儀器
  • 建筑節能類試驗儀器
  • 塑料管材檢測試驗機
  • 試驗儀器匯總
  • 斷路器照明開關檢測設備
展開

你的位置:首頁 > 技術文章

技術文章
  • 2022

    11-10

    堿骨料試驗箱操作規程

    JKS堿骨料試驗箱操作規程1、拆包裝后查看外殼,電器有無受損,使用前用硬塊將箱體擱起,切砂放在電器箱下,并調整水平。2、箱內加入清潔水其水位超過擱板17-22cm,同時考慮,放入堿液桶所增加容積,以免水溢入堿液桶內,降低堿液比例,而影響試驗質量。3、接通380≈穩壓電源,電源采用三相四線制,零線,如工作零線,箱體必須有可靠接地,必須達到國家有關安全用電標準后可使用。4、檢查出廠溫度設定值:溫度設定80℃,時間設定:672小時,如需修改請參照儀表設定方法重新設定。5、打開電源開...
  • 2022

    11-9

    索式萃取器操作規程

    索氏萃取器使用說明書索氏萃取器是按照GB328中,關于防水卷材可溶物含量分析而設計的專用儀器。是各種防水卷材物理檢驗的儀器設備,它的加熱裝置采用電熱套加熱,溫度可調,無明火,更具有安全性。一、結構組成:索氏萃取器主要由提取瓶、提取管、冷凝器三部分組成的,提取管兩側分別有虹吸管和連接管。各部分連接處要嚴密不能漏氣。提取時,將待測樣品包在脫脂濾紙包內,放入提取管內。提取瓶內加入石油醚,加熱提取瓶,石油醚氣化,由連接管上升進入冷凝器,凝成液體滴入提取管內,浸提樣品中的脂類物質。待提...
  • 2022

    11-7

    分體混凝土快速凍融試驗機操作規程

    混凝土快速凍融試驗機操作規程一、確認試驗箱體中防凍液性能良好,并確認防凍液液面能夠與試樣桶中試件上表面至少齊平;二、準備一個試件用做中心試件,并將中心試件溫度傳感器預埋到該試件中;將該試件放入到試驗箱體中心位置的橡膠桶內;三、取出養護并進行過泡水處理的試件,用量程為15kg的電子稱對試件稱重并逐一編號;四、3個一組,同時對試件進行彈性模量測定,并做好相應記錄。五、將套好橡膠筒的試件放入試驗箱中,向橡皮筒中試件注水,以沒過試件5mm為宜。中心試件注入防凍液。試驗箱中試件必須裝滿...
  • 2022

    11-4

    微機控制電子萬能試驗機操作規程

    WDW-30微機控制電子萬能試驗機操作規程1.首先接通電源,開啟電源開關后,電源指示燈亮。2.需要待機5分鐘,等萬能試驗機預熱穩定后打開電腦軟件聯機。3.試驗機裝配符合國標檢測的試驗夾具,以實際情況為準。4.試樣的制備,在待檢產品上截取長度復合測試標準規定,樣條不得有破損。5.試樣的測量,測量試樣的長度、寬度、厚度。取各參數的平均值。記錄數據。6.編輯程序,根據測試標準輸入測試速度和原始標距確定試驗方案。檢查實驗儀器的工作是否正常。7.試樣的安裝,調整好夾具,夾好試樣上端。再...
  • 2022

    11-3

    混凝土蒸汽快速養護箱操作規程

    蒸汽養護箱操作規程:1.將加熱水箱的管接頭與自來水管連接好,小量開啟水閥連續供水且無漏水現象。2.將試件架放入試驗箱內,帶模試件在試件架上均勻擺放,放入下層試件架時,嚴禁碰觸箱內溫度傳感器。3.接通電源,打開開關,設置儀表參數。靜置溫度值(SV1)最好設置為等于環境溫度,因為該情況下,靜置時間最準確。靜置溫度值(SV1)設置大于環境溫度時,需等加熱箱內產生蒸汽,使試驗箱內溫度達到設定溫度時才能進入靜置時間段開始計時,等待時間較長。靜置溫度值(SV1)設置小于環境溫度時,因設備...
  • 2022

    10-26

    水泥膠砂振實臺操作規程

    水泥膠沙振實臺操作規程1.檢查準備1.1檢查儀器設備及電源是否正常,所需工具是否齊全,1.2檢查試驗環境、條件是否符合要求。1.3檢查砂漿是否制備好。2.操作程序2.1接好電源,使儀器設備處于待工作狀態。2.2把組裝好的試模放到振實臺的臺面上,放下模套,使試模與模套對齊,把模套的壓把入位,擰緊壓模的螺絲,卡緊試模。2.3把攪拌好的砂漿分二層加入試模,第一層加入后,用大撥料器撥平,按下振實臺程控器的“開”按鈕,振實60次,然后再加入第二層膠砂,用小撥料器撥平后,開動控制器,振實...
  • 2022

    10-21

    SYD-0620瀝青動力粘度計操作規程

    SYD-0620瀝青動力粘度計操作規程1.將加熱的黏度計置一個容器中,然后將熱瀝青試樣自裝料管A注入毛細管粘度計,試樣應不致粘在管壁上,并使試樣液面在E標線處±2mm之內。2.將裝好試樣的毛細管黏度計放回電烘箱(135℃±5.5℃)中,保溫10min±2min,以使管中試樣所產生氣泡逸出。3.從烘箱中取出3只毛細管黏度計,在室溫條件下冷你卻2min后,安裝在保持試驗溫度的恒溫水槽中,其位置應使I標線在水槽液面以下至少為20mm。自烘箱...
  • 2022

    10-19

    SHR-650IV 水泥水化熱測定儀操作規程

    SHR-650IV型水泥水化熱測定儀操作規程一、熱量計熱容量的標定1、使用貝氏溫度計試驗前用量熱溫度計檢查貝氏溫度計零點;使用量熱溫度計時,不需調整零點,直接測定。2、在標定熱量計熱容量的前24h將保溫瓶放入內筒中,酸液攪拌棒放入保溫瓶內,蓋緊內筒蓋,再將內筒放入恒溫水槽內;調整酸液攪拌棒懸臂梁使夾頭對準內筒中心孔,并將酸液攪拌棒夾緊;在恒溫水槽內加水使水面高出試驗內筒蓋,由溢流管控制高度,打開循環水泵等,使恒溫水槽內的水溫調整并保持到(20±0.1)℃,然后關...
  • 2022

    10-18

    HWY-30高低溫水浴操作規程

    HWY-30高低溫水浴操作規程1.使用時應拿開上蓋加入水或防凍液,加至離頂蓋上口3cm為止。2.連接好外部需要冷卻的實驗設備并將外部需冷卻的實驗設備的進水口與低溫恒溫槽的出水口相連接然后將外部需冷卻的實驗設備的出水口與低溫恒溫槽的進水口相連,連接用的水管最好采用保溫軟管,此時是一個密閉的循環系統。3.水箱加水后打開電源開關,長按循環鍵2秒打開循環此時加熱自動開啟,長按制冷鍵2秒打開制冷,再次長按2秒即可關閉制冷。4.如果只用來冷卻樣品,可將樣品直接放入水槽內,只要把該高低溫水...
  • 2022

    10-17

    一文解析混凝土快速凍融試驗機的安裝與使用

    混凝土快速凍融試驗機的安裝和使用方法如下:1、開箱后,檢查是否有運輸振動造成的損壞,并在使用前修復損壞的零件。2、本設備安裝地點要求:①空氣應循環。②遠離熱源,避免陽光直射,防止雨淋。③設備周圍應有適當的空間,以便于操作、維護和空氣循環。3、本設備試驗周期長,應采用專用線供電,開關電壓穩定,接地可靠。4、設備應由專人操作并定期監控。5、將設置好的凝固試件放入試驗筒中,在15℃-20℃水中浸泡4天,然后取出。用濕布擦拭地表水,測量重量,并測量橫向基頻的初始值。然后將試件放入試件...
共 713 條記錄,當前 1 / 72 頁  首頁  上一頁  下一頁  末頁  跳轉到第頁 
??
在線咨詢
QQ客服1
QQ:280893268
電話咨詢
13501151717
關注微信
色老板最新地址2017影院
<ins id="ukspj"><form id="ukspj"></form></ins>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><xmp id="ukspj"><form id="ukspj"></form><ins id="ukspj"><form id="ukspj"><form id="ukspj"></form></form></ins>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form><ins id="ukspj"><form id="ukspj"></form></ins>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><ins id="ukspj"></ins><ins id="ukspj"><form id="ukspj"><ins id="ukspj"></ins></form></ins>
<xmp id="ukspj"><button id="ukspj"></button>
<xmp id="ukspj"><form id="ukspj"></form>
<ins id="ukspj"></ins>
<form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><ins id="ukspj"></ins>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form><xmp id="ukspj"><button id="ukspj"></button><xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj">
<xmp id="ukspj">
<form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form><xmp id="ukspj"><form id="ukspj"></form>
<xmp id="ukspj"><form id="ukspj"><button id="ukspj"></button></form>
<xmp id="ukspj">
<xmp id="ukspj"><button id="ukspj"></button>
<xmp id="ukspj"><form id="ukspj"><form id="ukspj"></form></form>
<xmp id="ukspj"><form id="ukspj"><form id="ukspj"></form></form>